Correcting sensor sampling delay on Soyo H610M

I thought my software was lying to me until I compared two data sets. In test report NO.MJ-SAMP-22, HWiNFO revealed that the default 2000ms sampling interval was missing peak temperature spikes during combat. I went into the sensor settings and forced the refresh rate for all core temps and voltages to 250ms. Checking the AIDA64 real-time curves, the jagged steps turned into smooth lines, and sync latency dropped from 400ms to a range of 110ms - 130ms. Be careful though: cranking the sampling rate this high adds a 2% - 4% CPU overhead, which can cause tiny frame jitters in competitive matches. I eventually settled on 500ms for core voltage and 1000ms for others to balance real-time accuracy without choking the system.
Category:Real-time Monitoring Last updated:March 31, 2026 9:52 AM